RS-232 Control for AV Devices

RS-232 is a standard for serial communication commonly used in AV systems to control TVs, projectors, PTZ cameras, and other devices. It allows precise, reliable, and bi-directional communication between a controller (e.g., a computer, control system, or automation device) and the target device over a physical cable.


Why Use RS-232?

  1. Reliability: Unlike IR, RS-232 commands are less prone to interference.
  2. Bi-Directional Communication: Devices can send feedback to the controller (e.g., status reports).
  3. Customizable: Commands can be tailored for specific functions.
  4. Long Cable Runs: RS-232 can transmit data over longer distances compared to other control methods.

How RS-232 Works

  • Cable Connection: RS-232 typically uses a 9-pin DB9 connector, though some devices use a 3.5mm TRS jack or terminal block.
  • Signal Protocol: Communication is based on a set baud rate (e.g., 9600 bps), parity, data bits, and stop bits. Typical settings are:
    • Baud Rate: 9600
    • Data Bits: 8
    • Parity: None
    • Stop Bits: 1
    • Flow Control: None
  • Command Format: Commands are sent as strings of text or hexadecimal bytes.

Common RS-232 Commands

RS-232 commands vary by device and manufacturer but typically follow a standard structure. Below are common commands for TVs, projectors, and PTZ cameras.

1. Power Control

  • Power On:
    Command: PON or POWR 1
    Example (HEX): 0x50 0x4F 0x4E
  • Power Off:
    Command: POF or POWR 0
    Example (HEX): 0x50 0x4F 0x46

2. Input Selection

  • Switch to HDMI 1:
    Command: INPUT HDMI1 or INPT 1
    Example (HEX): 0x49 0x4E 0x50 0x54 0x31
  • Switch to VGA:
    Command: INPUT VGA or INPT 3

3. Volume Control

  • Volume Up:
    Command: VOLU
    Example (HEX): 0x56 0x4F 0x4C 0x55
  • Volume Down:
    Command: VOLD
  • Set Volume Level:
    Command: VOL 50 (sets volume to 50%).

4. Mute Control

  • Mute On:
    Command: MUTE 1 or MUT ON
    Example (HEX): 0x4D 0x55 0x54 0x45 0x20 0x31
  • Mute Off:
    Command: MUTE 0 or MUT OFF

5. Status Requests

  • Power Status:
    Command: QPW (Query Power Status)
    Response: POWR 1 (on) or POWR 0 (off)
  • Input Status:
    Command: QIN
    Response: HDMI1, VGA, etc.

6. Projector-Specific Commands

  • Lamp On:
    Command: LAMP ON
  • Lamp Off:
    Command: LAMP OFF
  • Check Lamp Hours:
    Command: LAMP?
    Response: LAMP=1500 (hours used).
  • Shutter Open/Close:
    Command: SHUT 1 (open) / SHUT 0 (close).

7. PTZ Camera Commands

  • Pan/Tilt Control:
    • Pan Left: PAN LEFT
    • Pan Right: PAN RIGHT
    • Tilt Up: TILT UP
    • Tilt Down: TILT DOWN
      Example (HEX): 0x50 0x41 0x4E 0x20 0x4C 0x45 0x46 0x54
  • Zoom Control:
    • Zoom In: ZOOM IN
    • Zoom Out: ZOOM OUT
  • Set Preset:
    Command: PRESET 1 (sets current position as preset 1).
  • Recall Preset:
    Command: GOTO 1.

8. Device Reboot

  • Restart Device:
    Command: REBOOT or RST

Setting Up RS-232 Control

Step 1: Establish a Physical Connection

  • Connect the controller to the device using an RS-232 cable. Match the pins:
    • Tx (Transmit) on the controller to Rx (Receive) on the device.
    • Rx (Receive) on the controller to Tx (Transmit) on the device.
    • Ground (GND) to GND.

Step 2: Configure Communication Parameters

  • Use the manufacturer’s manual to configure the baud rate, data bits, parity, and stop bits in your controller software or terminal emulator (e.g., PuTTY, Tera Term).

Step 3: Send Commands

  • Open a terminal emulator or control software.
  • Input the command and press “Enter” or send it as raw bytes in HEX.

Step 4: Test Communication

  • Begin with simple queries like power status (QPW) to confirm the connection.

Common Tools for RS-232 Control

  • Terminal Emulators: PuTTY, Tera Term, or RealTerm.
  • Control Systems: Crestron, AMX, Extron, or Control4.
  • Debugging Tools: RS-232 protocol analyzers or USB-to-RS-232 adapters.

Best Practices

  1. Read the Manual: Each device has unique commands—consult its RS-232 guide.
  2. Test Incrementally: Verify communication with basic commands before moving to advanced setups.
  3. Cable Length: RS-232 works best under 50 feet; for longer distances, use RS-422/485 or repeaters.
  4. Document Configurations: Record settings like baud rate and parity for future reference.